Timers

Timers are used to provide timing information within your workspace. Timers can ben operated in Stopwatch or Countdown mode. In Countdown mode a start time is set to count from.

All time formats must be Hours, Minutes, Seconds with the preceding zero (HH:mm:ss) up to a maximum value of 23:59:59. Timers will continue to run when changing page and if the app enters the background.

Timers can be controlled from external systems using OSC, see commands below.

Response Methods

Use external applications to operate this control with OSC.

Send the string /ctrl/control/[uid]/[command] with the control's UID and selected command

Response Commands

Command
/theme [Int] Change the theme of the control (Int 1 to 14)
/theme [Int] [String] Change the theme of the control using custom palette name (Int 1 to 14)
/start Start the stopwatch or countdown timer
/pause Pause the stopwatch or countdown timer
/toggle Toggle the stopwatch or countdown timer between running and paused
/reset Reset the stopwatch or countdown timer
/set [HH:mm:ss] Set the start time of stopwatch or countdown timer (Timer must be stopped before setting)